Vantage Connect
Vantage Connect

General
Cellular Bands
3G UMTS (6622): 800, 850, 900, AWS1700, 1900, 2100MHz
Operating Temperature
-40° to +140°F; -40° to +60°C
Storage Temperature
-40° to +140°F; -40° to +60°C
Average Current Draw
20 - 30 mA
Peak Current
2 A
Housing Material
Rugged ASA Plastic
Dimensions (Width x Length x Height)
13.75 x 10 x 4.17 inches; 34.9 x 25.4 x 10.6 cm

Weight
8.14 lbs. (3.69 kg)
Solar Panel (@ 1000 w/m2)
Nominal power: 5 W
Voc: 21.6 V
Isc: 300 mA
Vmp: 18 V
Imp: 277 mA
Battery
Replacement Part Number
7011.025
Battery Voltage
6 volts
Battery Capacity
12 Ah
Charging Temperature
-4 to +120°F; -20 to +49°C
Estimated Battery Run Time (no solar charging, at 25°C)
Wireless: 16 - 21 days
Cabled: 14 - 17 days
Charging Circuit
High-efficiency switching charger
Maximum-Peak-Power-Tracking (MPPT) at 18V - Typical for 12V solar-panel
Charges 6V SLA battery @ 2A max
Charging voltage temperature compensation
Low- and high-temperature charging cut-out
Low-battery load disconnect
Reverse battery protection
Designed to have multiple batteries and/or solar-panels added in parallel to extend capacities
Wireless Communications
Receive Frequency
US Models: 902 - 928 MHz FHSS
EU Models: 868.0 - 868.6 MHz FHSS
Australia/Brazil Models: 918.0 - 926.0 MHz FHSS
New Zealand Models: 921.0 - 928.0 MHz FHSS
Japan Models: 928.15 - 929.65 MHz FHSS
India Models: 865.0 - 867.0 MHz FHSS
ID Codes Available
8
Range
Line of Sight: Up to 1000 feet (300 m)
Through Walls: 200 to 400 feet (60 to 120 m)
Certifications
FCC
PTCRB
CE
Carrier
Package Dimensions
Package Dimensions (Length x Width x Height)
15.0" x 11.5" x 5.5”; 38.1 x 29.2 x 14.0 cm
Package Weight
10 lb. 10 oz (4.8 kg)
Sensor Data (Internal Sensors)
Barometric Pressure
Resolution and Units
0.01" Hg, 0.1 mm, 0.1 hPa, 0.1mb. (user selectable)
Range
16.00" to 32.50" Hg, 410 to 820 mm Hg, 540 to 1100 hPa or mb
Elevation Range
-1500' to +15,300' (-460 m to 4670 m)
Accuracy
At -40° to +32°F (-40° to 0°C): -0.06/+0.15" Hg (-1.5 /+3.8 mmHg; -2/+5 hPa/mb)
At +32° to +122°F (0° to +50°C): ±0.03" Hg (±0.8 mm Hg, ±1 hPa/mb)
At +122° to +140°F (+50° to +60°C): -0.06/+0.15" Hg (-1.5 /+3.8 mmHg; -2/+5 hPa/mb)
Sea-Level Reduction Equation Used
United States Method employed prior to use of current "R Factor" method
Equation Source
Smithsonian Meteorological Tables
Equation Accuracy
±0.01" Hg (±0.3 mm Hg, ±0.3 hPa/mb)
Elevation Accuracy Required
±10' (3m) to meet equation accuracy specification
Trend (change in 3 hours)
Change ±0.06" (2.0 hPa/mb, 1.5 mm Hg) = Rapidly
Change ±0.02" (0.7 hPa/mb, 0.5 mm Hg) = Slowly
Trend Indication
5 position arrow: Rising (rapidly or slowly), Steady, or Falling (rapidly or slowly)
Update Interval
Based on data plan
Alarms
High Threshold from Current Trend for Storm Clearing (Rising Trend)
Low Threshold from Current Trend for Storm Warning (Falling Trend)
Range for Rising and Falling Trend Alarms
0.01 to 0.25" Hg (0.1 to 6.4 mm Hg, 0.1 to 8.5 hPa/mb)
Inside Relative Humidity
Resolution and Units
1%
Range
1 to 100% RH
Accuracy
±3% from 1% to 90%; ±5% from 90% to 100%
Update Interval
Based on data plan
Alarms
High and Low Thresholds from Instant Reading
Inside Temperature (or optional external temperature probe)
Resolution and Units
Current Data: 0.1°; °C is converted from °F and rounded to the nearest 0.1°C.
Alarms: 1°; °C is converted from °F and rounded to the nearest 1°C.
Range
Inside: -40° to +140°F (-40° to +60°C)
External Temperature Probe: -40° to +150°F (-40° to +65°C)
Sensor Accuracy
±1°F (±0.5°C) typical
Update Interval
Based on data plan
Alarms
High and Low Thresholds from Instant Reading
Warranty
We warrant our products to be free of defects in material and workmanship for one year from the date of original purchase. During the warranty period, we will, at our option, either repair or replace the product free of charge. This warranty does not cover damage due to improper installation or use, lightning, negligence, accident, unauthorized service, or to damages beyond the Davis products themselves.
Learn more